• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar

PMS Instrument Company

  • Home
  • About Us
    • Biography of Henry Dixon
    • Biography of John Joly
    • Biography of Per Scholander
    • History of PMS Instrument – Joe Zaerr
    • History of the Scholander Pressure Chamber
  • Products
    • Model 600
    • Model 600D
    • Model 600-EXP Super Chamber
    • Model 615
    • Model 615D
    • Model 670
    • Model 1000
    • Model 1505D
    • Model 1505D-EXP
    • Model 1515D
    • Pump-Up Chamber
  • Agriculture
    • Using a Pressure Chamber with wine grapes
    • Using a Pressure Chamber with Almond
    • Using a Pressure Chamber with Walnuts
    • Using a Pressure Chamber with Prunes
    • Stress levels, crop tables and information
  • Maintenance
  • Resources
    • References
  • How to Order
  • Contact Us
  • Show Search
Hide Search
You are here: Home / Instrument Maintenance / Maintenance for the Portable Tank

Maintenance for the Portable Tank

Warning!Important Safety Information
« Click Here

The portable tank should be inspected along with the instrument, but it requires additional attention. Because the tank is a pressure vessel, care should be taken to insure that it is not dented or dropped. If the valve should be inadvertently knocked off, the tank could become a rocket and cause great damage. US Department of Transportation (DOT) regulations require that the tank receive a hydrostatic test every five years. The last date tested is stamped on the top (shoulder) of the cylinder body. Most compressed gas supply stores can perform this pressure test. If it is not possible to have the tank tested locally, return it to PMS Instrument Company for testing and inspection.

Primary Sidebar

Maintenance Topics:

  • Instrument Maintenance
    • Adjusting the “Brass” – Control Valve
    • Adjusting the “Stainless Steel” – Control Valve
    • Cleaning the O-Ring on the lid
    • Cleaning the Safety Valve
    • Digital Gauge Battery Replacement
    • Instrument Quick-Connect Couplers
    • Maintenance for Compression Gland Lid
    • Maintenance for the Portable Tank
    • Testing the instruments safety features
  • Maintenance for the Pump-Up Chamber
    • Pump-Up Chamber is leaking
    • Pump-Up Chamber will not increase in pressure
    • Basic Maintenance of Pump-Up Chamber
    • Changing O-ring on Lid of Pump-Up Chamber
    • Changing Piston Cup on Pump-Up Chamber
    • Lubricating the piston of the Pump-Up Chamber

Copyright © 2025 PMS Instrument Company | LOGIN